Gear position 1
 
When gear lever position 1 is selected, the manual valve directs fluid at line pressure to the front clutch and to the rear band servo.
 
1-2 shift valve The 1-2 shift valve has a lower valve section and an upper section plug and spring.
2-3 shift valve assembly
 
The 2-3 shift valve assembly consists of the shift valve, its' spring and a throttle pressure regulating plug.
 
The servo orifice control valve
 
The servo orifice control valve is a shuttle valve which can be positioned at rest by a spring or can be moved by governor pressure.
 
3-2 kickdown
 